Patient Overlap Inflates Breast Thermography AI Scores

When the same patient's images land in both the training and test sets, breast thermography AI scores jump by 5 to 13 AUC points, a Scientific Reports audit of two public datasets found.

TML News DeskNov 24, 4:15 PM ET · 2 min read
A thermographic image. Breast thermography models that train and test on images of the same patients report scores inflated by up to 13 points, an audit found. Image: Wikimedia Commons.
Summary

The model wasn't reading tumors. It was recognizing patients.

Tap a passage. React to the part that matters.

Breast thermography AI scores inflated by up to 13 points when a patient's images appeared in both training and test sets.

Thermography cameras take many images of each patient, frontal, lateral and oblique views of the same breasts. Every patient also carries a personal thermal baseline, a heat pattern that's hers before any disease enters the picture. When researchers split a dataset by image instead of by patient, some of her images train the model and others test it, and the model can pass by recognizing the patient rather than reading the disease. A Scientific Reports audit set out to measure how much that shortcut is worth.

The team ran two public datasets under both splitting rules. DMR-IR holds 5,444 thermal images from 214 patients in Brazil. The Mendeley collection holds 357 images from 119 patients in Colombia. Each dataset went through image-level cross-validation, which lets a patient land on both sides, and patient-level cross-validation, which keeps every image of a patient on one side only. Four neural network architectures and two preprocessing pipelines ran under both protocols, with corrected statistical tests.

The shortcut was worth 4.8 AUC points in DMR-IR, with a 95 percent confidence interval of 3.7 to 5.5, and 12.6 points in the Mendeley data, with an interval of 8.3 to 16.2. The direction surprised the team. DMR-IR carried near-total patient overlap, a Jaccard index of 0.972, and produced the smaller inflation. Mendeley carried an index of 0.467 and inflated 2.6 times more. Under patient-level splitting, DMR-IR performance fell to an AUC of 0.94 to 0.96.

A controlled run inside DMR-IR explains part of the puzzle. The researchers dialed patient overlap from zero to 0.947 by swapping images between sets, and inflation climbed fast, then flattened. Partial leakage does most of the damage early, so the overlap figure printed in a paper can't by itself tell a reader how inflated its scores are. A physics-based preprocessing pipeline, built on the radiometric T^4 transform, didn't remove the inflation either. The split decides the result, not the image preparation.

The authors are careful about what two datasets can't prove. DMR-IR and Mendeley differ in image resolution, views per patient, institution, acquisition protocol, sample size and class balance, so the 2.6-fold gap can't be assigned to any single trait. The audit also doesn't judge thermography as a clinical tool. It judges the tests behind the published AI scores, some of which report AUC values near 1.0 against pooled clinical estimates of 88.5 percent sensitivity and 71.8 percent specificity.

The fix the paper asks for is disclosure. Reporting standards for medical AI, CLAIM and TRIPOD-AI, already call for the partitioning method and patient overlap to be stated, and overlap figures are rarely reported in this literature. A thermography score published without them is a number without its conditions attached.