Defibrillator Guided By Heart Scans Misses Main Goal
Over a median 6.3 years, sudden death or a dangerous rhythm hit 7.8 percent of the defibrillator group and 9.2 percent of the monitored group, a gap the trial couldn't confirm.
The scan found the scar. The device didn't settle it.
Implanting defibrillators in patients picked by heart scar scans didn't significantly cut sudden death or dangerous rhythms in a 353-person trial.
Selvanayagam and colleagues ran the open-label trial at 18 sites in Australia, Germany and the United Kingdom, enrolling adults between 2015 and 2022, and published it in JAMA on November 17. Every participant had a pumping efficiency, measured as left ventricular ejection fraction, between 36 and 50 percent, above the 35 percent cutoff where guidelines recommend a defibrillator, and every one had scar visible on cardiac magnetic resonance imaging. Half received an implantable defibrillator (180 patients) and half an implantable loop recorder that monitors rhythm without treating it (173 patients).
Over a median follow-up of 6.3 years, the main outcome, sudden cardiac death or a hemodynamically significant ventricular arrhythmia, occurred in 14 patients in the defibrillator group (7.8 percent) and 16 in the recorder group (9.2 percent). The hazard ratio of 0.76 came with a confidence interval from 0.37 to 1.58, too wide to confirm a benefit. Deaths from any cause, cardiovascular deaths and heart failure hospitalizations ran similar in the two groups.
The components of that outcome pulled apart. Sudden cardiac death occurred in 3 defibrillator patients (1.7 percent) against 10 recorder patients (5.8 percent), a hazard ratio of 0.26. The dangerous-rhythm component ran the other way, 12 patients (6.7 percent) against 6 (3.5 percent). A prespecified age split also diverged: among patients under 70 the main outcome favored the defibrillator, 3.3 percent against 10.0 percent, while among those 70 and older it favored the recorder, 16.9 percent against 7.5 percent (P=.01 for the interaction). Subgroup splits of 30 total events can mislead, and the authors don't rest their conclusion on them.
The trial's size is its central limit. Thirty main-outcome events across 353 patients can't settle a question that guidelines currently answer with the 35 percent cutoff, and the open-label design meant patients and doctors knew who carried a device. The participants, median age 65 and 18 percent women, were also drawn from three countries' clinic populations, all already on guideline-directed drug therapy.
The scar-based strategy stays unproven at this scale. Many sudden deaths happen in exactly this ejection-fraction range, which is why the question matters, but this trial gives doctors no basis to implant defibrillators above the current threshold on the strength of a scar scan alone.